Description

The Plan for Riverfront redevelopment of Lagos predicted a car park with two underground floors. The alternative solution was the implementation of a continuous retain wall of CSM armed and a single level of anchors to replace piles of 800 mm spaced by 1 m and jet-grouting columns of 800 mm between the piles.

Project Owner

EL - Estacionamentos de Lagos, S.A.

Location

Lagos, Portugal

Special Works

  • 6500 m³ Cutter Soil Mixing
  • 1700 m³ Jet-Grouting
  • 1944 ml anchors 600 kN
  • 3810 ml micropiles GEWI 65mm